Din Rail Energy Meter

Home >  Products >  Din Rail Energy Meter

LCD Display CE IEC Electrical Instruments 2p Type Din Rail Energy Meter kwh Meter for Din Rail kWh Electric Meter.

The meter has RS485 remote reading function and the following optional functions (blue backlight, to display power failure, total power, current, voltage, power, power factor, frequency, etc.) and can accurately measure active energy. The energy meter has...
  • Description
  • Specification
  • Quick Detail
  • Applications
  • Competitive Advantage
  • Related products
  • Inquiry
Description

The meter has RS485 remote reading function and the following optional functions (blue backlight, to display power failure, total power, current, voltage, power, power factor, frequency, etc.) and can accurately measure active energy. The energy meter has a large screen LCD screen.

The single-phase two-wire din-rail energy meter also has a pulse output independent of the internal circuit. The port 21 of the meter is connected to the positive pole, and the port 20 is connected to the negative pole. The port 23 is the positive pole of RS485, and the port 24 is the negative pole of RS485. The circuit requires a voltage of 5~27V DC and a maximum current of 27 mA DC.

1.9.4 RS485 Communication Meter Reading Application (Communication Protocol) and Register Address

The meter can remotely record data such as electric energy in the meter through his RS485 interface and transcribe the electric energy data in the meter at close range with the handheld computer through its infrared communication interfac. The encoding format, parity (even parity) and data transmission mode (eight data bits, one stop bit) meet the MODBUS-RTU standard requirements. The communication baud rate can be 1200bps, 2400bps, 4800bps or 9600bps (default). If there is no special requirement, the meter is set according to the default baud rate of 9600bps. The meter address and communication baud rate can be modified by the software we provide.

1Data Format:

Address + Function Code +Data +CRC Check code

2Register Type

The meter uses two types of registers, independently addressed.

The first type is the data register, read-only, using command code 0x04 to read.

The second type is the parameter register, which is readable and writable, read using command code 0x03, and set using command code 0x10.

3Data Format

Float type dataThe data read from the meter conforms to the IEEE-754 standard floating-point number, and the data format is a 32-bit 4-byte single-precision floating-point data format

4.Data Register List

Data Register Address Register Description
High Byte Low Byte Description Unit Format Mode
0 0 Voltage V floating-point read only
0 8 Current A floating-point read only
0 12 Active Power Kw floating-point read only
0 1A Reactive Power Var floating-point read only
0 2A Power Factor floating-point read only
0 36 Frequency Hz floating-point read only
1 0 Total Active Power Kwh floating-point read only
4 0 Total Reactive Power Kvarh floating-point read only


5.Parameter Register List

Parameterregister address

RegisterDescription

HighByte

LowByte

Description

Format

Mode

00

00

Baudrate (1200 2400 4800 9600)

floating-point

read,wright

00

02

Checkdigit (0: even 1: odd 2: none)

floating-point

read,wright

00

08

Communicationaddress (meter number 1-247)

floating-point

read,wright

00

10

Relaycontrol (1: switch on 2: switch out)

floating-point

read,wright


Specification

图片1

A: Front panel

B: Cover

C:Bottom

D: Seal

Front panel       Flame-retardant PC

Cover            Flame-retardant ABSor PC

Bottom           Flame-retardant ABSor PC

Dimension89.9mmx35mmX72mm

Weight0.12Kg (Net Weight)

图片2 拷贝

Terminal

Notice

1/3

Input/output

4/5

RS485 port

6/7

Pulseoutput

8/9

Neutral line

1MODULES(Note:This model have not set button)

图片3 拷贝

A: Front panel

B: Cover

C:Bottom

D: Seal

Front panel       Flame-retardant PC

Cover            Flame-retardant ABSor PC

Bottom           Flame-retardant ABSor PC

Dimension100mmx35mmX65mm

Weight0.2 Kg (Net Weight)

图片4 拷贝

Terminal

Notice

1/2

Input/output

3/4


20/21

Pulseoutput

23/24

RS485 port

2 MODULES

图片5

A: Front panel

B: Cover

C:Bottom

D: Seal

Front panel       Flame-retardant PC

Cover            Flame-retardant ABSor PC

Bottom           Flame-retardant ABSor PC

Dimension100mmx76mmX65mm

Weight0.35Kg (Net Weight)

图片6

Terminal

Notice

L1/L1

Input/output

N/N

Input/output

1/2

Pulseoutput

3/4

RS485 port


Quick Detail

AC1A, 5A Current rating,126*97mm Dimensions , 40~60Hz frequency WithMODRUS-RTU protocol Internal Power Consumption is ≤2W / 10VA ,International standard IEC 62053-21,Operating Voltage is 181/279V AC (3~)

Applications

din rail energy meter modbus

din rail energy meter

din rail mounted energy meter

din rail mounted energy meter india

abb din rail energy meter

single phase din rail energy meter


Competitive Advantage

The meter can remotely record data such as electric energy in the meter through his RS485 interface and transcribe the electric energy data in the meter at close range with the handheld computer through its infrared communication interfac. The encoding format, parity (even parity) and data transmission mode (eight data bits, one stop bit) meet the MODBUS-RTU standard requirements. The communication baud rate can be 1200bps, 2400bps, 4800bps or 9600bps (default). If there is no special requirement, the meter is set according to the default baud rate of 9600bps. The meter address and communication baud rate can be modified by the software we provide.


Inquiry

GET IN TOUCH